Product Details:
Place of Origin: china
Brand Name: sonostar
Certification: ce
Description
(R/F X-ray System)
Model: MCX-RF05C
R/F Medical X-ray Equipment
 
Application R/F X-ray System
The equipment has the function of fluoroscopy and spot film radiography, which can be applied for the radiography of alimentary tract, biliary tract, urinary tract, veins of lower extremity and so on. It can also operate on the reposition of fracture and take the corpus alienum under the pattern of fluoroscopy. 
 
Specifications of the R/F Medical X-ray Equipment
Power Supply 
Voltage: 380V±38V, Frequency: 50Hz±1Hz, Capacity: ≥40kVA
Internal Resistance: ≤0.17Ω
 
X-ray High Voltage System
Radiography
Tube Voltage: 44kV~125kV, totally 41 grades
Tube Current: 32mA~500mA adjustable with different grades
Exposure Time: 0.02s~4s, totally 21 grades
Control Interface: LCD touch screen
Fluoroscopy
Tube Voltage: 44kV~110kV continuous adjustable with 2kV each grade
Tube Current: 0.5mA~5mA continuous adjustable
 
X-ray tube of the R/F X-ray System
Type: HXD52-30, 50/125, Power Output: 40kW (max), 20kW (min)
Anode Thermal Capacity: 140kJ, Assembly Thermal Capacity: 1100kJ
Rotary anode speed: 2700rpm, Focus: 2.0 (max), 1.0 (min)
Microcomputer-controlled upper tube remote control surgical bed
Movement range bed: 90°~0°~25°
Bed's transverse movement distance: ±110mm
Longitudinal movement distance of radiography frame and spot film device: ≥720mm
Focus to film distance (SID): 1500mm
Radiography dimension of whole film: 8”×10”~14” ×17”
Spot film division method: whole film, 2-division film, 3-division film, 4-division film
Method to control bed: remote control, bed-control, Soft boot and stay of frequency conversion
Collimator: Electric multi-leaf
Fixed grid for bed use: Grid density: 103L/INCH, Ratio: 10:1, Focal distance: 120cm, 15” ×18”
 
Digital TV system
EGA: 9” Toshiba, High resolution CCD (digital camera), imported ultra-low 0.47 MEGA PIXELS
Monitor: 14” medical high definition medical monitor, horizontal central resolution 1000 thread, edge 800 thread, video wideband 12.5mHz, 50bit, 25 pictures per second
Picture-process system: High definition and non-interlaced output, 8-grade noise reduction, 7 pictures in storage, LIH, mirror image rotation in vertical and horizontal, positive-negative image, OSD (monitor display)
 
Configuration of the R/F X-ray System:
Standard
Program-controlled 500mA remote control operating table (with touch screen control)             1 set
X-ray high voltage generating device :                                    1 set
Remote control diagnosis table                                           1 set
Toshiba 9'' image intensifier                                              1 set
Imported ultra-low luminosity digital CCD vidicon                            1 set
Medical high definition monitor                                           2 sets
Electric multi-leaf collimator                                              1 set
High voltage cable                                                      1 set
 
Optional of the R/F X-ray System:
Integrated radiography table / vertical bucky stand                   1 set for each
Digital image workstation                                                1 set
 