Product Details:
Place of Origin: china
Brand Name: sonostar
Certification: ce
Model Number: MBox-5 Wireless Patient Monitor(can work with computer, IPad)
Description
 
Model: MC-PMN5
 
Introduction:  
* 15"high resolution 1024 X 768 color TFT LCD display. * Touch screen * Large volume of tabular and graphic trends information easy to recall. * UP to 6 hours working capacity of built-in rechargeable 2 battery. * Options of Thermal Recorder, IBP, ETCO2 , 2-TEMP, Multi-gas, BIS, Necllor
 
Summary of features and benefits of the Modular patient Monitor:
 The state-of-the-art modular designmakes the flexible monitoring solution within reach
 Standard features you need, including15" large touch screen, 3/5 lead ECG,
NIBP, SPO2, Temperature, ST segment analysis
 Selectable screen layout of large fontdisplay, trend co-exist display,Oxy-CRG
display, full lead ECG display meet your various monitoring needs
 Comprehensive drug calculation andtitration table to calculate infusion rates
 Up to 168-hour graphical and numerictrends and 2-hour full disclosure can be displayed
 Select any of the optional extra modulesto meet your Department's needs: Dual IBP, Respironics mainstream/sidestreamETCO2, Nellcor SpO2, Phasein Multigas,Danmeter BIS
 Both wired or wireless capability of networking with Central Station
 
Performance Specification of the Modular patient Monitor: 
Display
Type and size: 12.1" Color TFT Touch Screen
Resolution: 1024*768
Maximum waveforms: 6
 
ECG
Lead type: 3-Lead or 5-Lead selectable
3 leadwire: I,II, or III
5 leadwire: I,II,III,V,AVR,AVL,AVF
Gain: ×0.25,×0.5,×1,×2,Auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Bandwidth(Surgery mode): 1-20Hz
Bandwidth(Monitoring mode): 0.5-40Hz
Bandwidth(Diagnostic mode): 0.05-130Hz
 
ECG derived HR:
Heart Rate for Adult: 15-300BPM
Heart Rate for Neonate/Pediatric: 15-350BPM
Heart Rate Accuracy: ±1BPM or ±1%, whichever is greater
 
Heart Rate Resulotion: 1BPM
ST Segment:
ST segment range: -2.0mv to 2.0mv
ST segment accuracy: -0.8mv to 0.8mv
ST analysis: 2-lead measurement
 
Pace
Pace detection: Yes
Pace rejection amplitude: ±2 mV ~ ±700mV
Pace rejection width: 0.1ms ~ 2ms
Pace rejection rise time: 10μs~100μs
 
Respiration of the Modular Patient monitoring systems:
Measurement technique: RA-LL Impedance variation detection
Range: Adult: 4~150rpm
Pediatric/Neonate: 7~150rpm
Apnea alarm: Yes, 10s,15s,20s,25s,30s,35s,40s selectable
 
SpO2
Nellcor OxiMax SpO2:
SpO2 measurement range: 1%~100%
Accuracy: ±2%(70%-100%); unspecified(0-69%)
Pulse Rate:
Measurement range: 20bpm~300bpm
Accuracy: ±3bpm
Zondan Pulse oximetry:
SpO2 measurement range: 35%~100%
PPR measurement range: 20bpm~300bpm 1bpm ±3bpm
Accuracy: ±2%(70%-100%); unspecified(0-69%)
 
IBP
Measuremen range: -10~300mmHg
Accuracy: ±1mmHg or ±2%, whichever is greater(without sensor)
Alarm range: -10~300mmHg
Pressure transducer:
Sensitivity: 5μv/V/mmHg
Impedance range: 300-3000Ω
 
NIBP(non-invasive blood pressure)
Measurement technique: Oscillometric
Auto cycle time: 0~4 Hours
Measurement unit: mmHg/kPa selectable
Systolic Range: Adult: 40-270mmHg;
Pediatric: 40-200mmHg;
Neonate: 40-135mmHg
Mean Range: Adult: 20-235mmHg;
Pediatric: 20-165mmHg;
Neonate: 20-110mmHg
Diastolic Range: Adult: 10-215mmHg;
Pediatric: 10-150mmHg;
Neonate: 10-100mmHg
Accuracy: 5%
Over-pressure protection:Double safety protection
 
Temperature:
Scale: ºCelsius(C) or ºFahrenheit(F)
Measurement range: 0~50ºC
Accuracy: ±0.1ºC
 
ETCO2
Mainstream CO2 (Respironics CAPNOSTAT 5)
Measurement range: 0-150mmHg
Accuracy: 0 to 40mmHg ±2mmHg
41 to 70mmHg ± 5% of the reading
71 to 100mmHg ±8% of the reading
101 to 150mmHg ±10% of the reading
RR range: 0 to 150rpm
Accuracy: 1rpm
Response time: <60ms
 
Sidestream CO2 (Respironics LoFIo)
Measurement range: 0-150mmHg
Accuracy: 0 to 40mmHg ±2mmHg
41 to 70mmHg ± 5% of the reading
71 to 100mmHg ±8% of the reading
101 to 150mmHg ±10% of the reading
Sample flowerate: 50ml/min
Accuracy: ±15% or 15ml/min,whichever is greater
Warm-up time: <1min,enter the iso accuracy mode
After 1 min,enter the full accuracy mode
RR range: 0-120rpm
RR accuracy: ±2 rpm
 
Standard :ECG, SpO2, NIBP, Resp, Temp, HR/PR,
1 piece of Li-ion battery.
 
Optional of the Modular patient Monitor : Nellcor SpO2, Dual-Temp, Second Li-ion battery, Thermal
recorder, Networking module, Dual-IBP, Respironics
Mainstream/Sidestream ETCO2, Multi-Gas, BIS
 
Contact Us