Sonostar Technologies Co., Limited
New Tec ,new Life Sonostar is a professional medical equipment manufacturer in China
Select Language
English
French
Italian
Spanish
Portuguese
Arabic
中文
Home Medical Pump

ASP-1800D Double Channel Syringe Pump

Browse Categories
Contact Us
Mr. leesun
504#, C Building, #27 Yayingshi Road, Science Town, Guangzhou, China.
I am Online Chat Now
Mr. leesun() Mr. leesun()

ASP-1800D Double Channel Syringe Pump

Product Details:
Brand Name: sonostar
Certification: ce
Model Number: airpro_178
Description

 

ASP-1800D Double Channel Syringe Pump

Features:
 
1. Universal syringe set: 5ml,10ml,20ml,30ml,50ml,60ml.
2. Automatically detection of syringe types and remained solution.
3. Broad range in delivery rate settings.
3. 6 Hours continuous work after fully charged.
4. Three levels of alarm volume: high, medium and low.
5. Three levels of occlusion pressure: high, medium and low.
6. KVO function:After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus. 
 
Technical Specifications:

 

PARAMETER SPECIFICATION
Applicable syringes 10ml,20ml,30ml,50ml,60ml of any standard
Accuracy +/- 2% with correct calibration
Rate mode 50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
Time Mode SOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode: Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range 0.1-1999.9ml (0.1 ml step)
Purge Rate
50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h
KVO Rate 1ml/h
Occlusion pressure Three level setting LOW, MEDIUM or HIGH
Alarms
Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate
10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Bolus Volume Maximum of 25ml
Interface RS-232, Reserved port
Power source
AC power supply: AC 100 to 240V( +/-10%)?50/60Hz;
Built-in Lithium Battery:  Rechargeable, 11.1V, 2000mAh.
6 hours of continuous operation.
Accessories: AC power line, Operational manual
Protection Class Class I, Type CF,IPX4
Dimension / Net weight 300mm*240mm*250mm , 3.6kg