ASP-1800 Syringe Pump

Product Details:
Brand Name: sonostar
Certification: ce
Model Number: airpro_175
Description

ASP-1800 Syringe Pump 

Features:
1. Compatible with syringes of any brand, 10ml~60ml.
2. Automatically calibration for syringes of any brand.
3.Three working modes: Rate control mode, Time control mode and Dose-Weight control mode.
4. Automatically detection of syringe types and settings.
5. Wide range in delivery rate settings.
6. 6 Hours continuous worked.
7. Three levels of alarm volume: high, medium and low.
8. Three levels of occlusion pressure: high, medium and low.
9. KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus.
 
Technical Specifications of ASP-1800 Syringe Pump
 
PARAMETER SPECIFICATION
Applicable syringes 10ml,20ml,30ml,50ml,60ml of any standard
Accuracy +/- 2% with correct calibration
Rate mode 50ml(60ml): 0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml): 0.1ml/h-800.0ml/h (0.1ml/h step)
5ml,10ml: 0.1ml/h-400.0ml/h (0.1ml/h step)
Time Mode SOL. VOL:0.1-999.9ml (0.1ml step)
TIME: 1-1999min (1min step)
Body Weight Mode: Volume: 0.1-999.9ml(0.1ml step)
DRUG MASS: 0.1-999.9mg(0.1mg step)
DOSE: 0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT: 0.1-300kg(0.1kg the least step)
Total Volume Range 0.1-1999.9ml (0.1 ml step)
Purge Rate
50ml(60ml): 1800.0ml/h,
20ml(30ml): 800.0ml/h,
10ml: 400.0ml/h  5ml: 200ml/h
KVO Rate 1ml/h
Occlusion pressure Three level setting LOW, MEDIUM or HIGH
Alarms
Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate
10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Bolus Volume Maximum of 25ml
Interface RS-232
Power source
AC power supply: AC 100 to 240V( +/-10%)?50/60Hz;
Built-in Lithium Battery:  Rechargeable, 11.1V, 2000mAh.
6 hours of continuous operation.
Accessories: AC power line, Operational manual
Protection Class Class I, Type CF,IPX4
Dimension / Net weight 280mm*160mm*130mm , 2.5kg