400ma diagnosis x ray equipment-MSLCX12

Product Details:
Place of Origin: china
Brand Name: sonostar
Certification: ce
Model Number: MSLCX12
Description

 

Product Details
 

Quick Details

Type: 400ma diagnosis x ray equipment-MSLCX12

Brand: MSL

Model number: MSLCX12

Place of origin: China

Fluoroscopy Voltage: 45-110KV continuous voltage

Supply power Capacity: 20KVA

Fluoroscopy Current: 0.3-5mA continuous currency

Supply power Frequency: 50Hz ± 1Hz

Radiography Current: 50-400mA shift

Radiography Voltage: 45-125KV continuous voltage

Radiography Time: 0.03-5s23 shift

X-Ray tube Model: XD 51-20,40 /125

Packaging & Delivery

Packaging detail : double standard export package

Delivery detail: within 7-10 workdays after receipt of payment

Specifications

fluoroscopy and radiography Machine 
X Ray machine 

diagnosis x ray

diagnosis x ray

 

Features:

 

1) Equipped with double diagnostic table and xray rubes, tube voltage is 125kV, tube currency is 400mA, single direct bridge full-wave commutation.

 

2) X-ray tube capacity protection, anode startingup protection and radiograph timelimit protection device semi-conduct controlled, fluoroscopy computed time device, xray tube overhot protecionare provided, ensure xray tube run safely long time, improve accuracy of kV mA S.

 

3) Bigger scope of rotation diagnostic table, movable table muliitem spotfilm device, easy to operate, radiation –proof, ensure operate and the tested.

 

4) Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.

 

5) Applied in all kinds of hospital for radiography such as general body,beam filtration,and chest.

 

 

Technology parameters:

 

 

Department

Technology parameters

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

Tube voltage

45-110KV continuous voltage

Radiography

Tube currency

50-400mA shift

Tube voltage

45-125KV continuous voltage

Exposure time

0.03-5s23 shift

Power

Voltage

380V±10%

Frequency

50Hz±1Hz

Capacity

≥30KVA

Inner resistance

≤0.3Ω

X-ray assembly

Type of x-ray

XD51-20.40/125

Focus

1×1.2×2 double focal

Rated rotate speed of anode

2800r/min

Changed beam limited device

Diagnosis table YS09D

Automatic, adjusted field of view

Radiograph table YS11S

Manually adjusted field of view, luminosity≥100LX

C15 Diagnostic table

Rotate of table

-15°~0°~90°automatic

Moving table

Automatic 700mm distance moving lengthways

Distance of focal table

400mm

High of table

820mm

Spot film device

Scope moving

Up and down

600mm

Left and right

±100mm

Forward and backward

300mm

Way of locking

Electromagnetism locking

Radiography item

5×7,8×10,10×12,11×14

CDGI Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

81

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5×7,8×10,10×12,11×14,

12×15,14×14,14×17

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

 Option

 

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

The minimum distance from focal spot

380mm

Radiography item

8”*10” 10”*12” 11”*14”12”*15”

14”*14” 14”*17”

Fixed beam filtration role

Grid density

40L/cm

Grid radio

10:01

Focal distance

180cm

- See more at: http://echowellmed.com/400ma-diagnosis-x-ray-equipmentmslcx12-p-320.html

 