Sales & Support: Request A Quote
Home ProductsPR electronics

PR electronics 3118 Bipolar isolated converter splitter origin in Denmark and short delivery time competitive price

PR electronics 3118 Bipolar isolated converter splitter origin in Denmark and short delivery time competitive price

    • PR electronics 3118 Bipolar isolated converter splitter origin in Denmark and short delivery time competitive price
    • PR electronics 3118 Bipolar isolated converter splitter origin in Denmark and short delivery time competitive price
  • PR electronics 3118 Bipolar isolated converter splitter origin in Denmark and short delivery time competitive price

    Product Details:

    Place of Origin: Denmark
    Brand Name: PR electronics
    Certification: ATEX 2014/34/EU
    Model Number: 3118

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: USD+120 +PIECE
    Packaging Details: 100% origin package
    Delivery Time: 2-3 weeks
    Payment Terms: TT,Paypal
    Supply Ability: 1000+piece+per week
    Contact Now
    Detailed Product Description
    Operating Temperature: -40°C To +80°C Calibration Temperature: 20...28°C
    Screw Terminal Torque: 1 Nm Max. Switching Frequency: 25 Hz

    PR electronics 3118 Bipolar isolated converter splitter
    Description
    PR electronics 3118 Bipolar isolated converter splitter
    Conversion of voltage and current bipolar process signals to
    uni-/bipolar signals
    Multiple signal ranges are selectable via DIP-switches
    Splitter function: 1 signal in and 2 signals out
    Excellent accuracy, better than 0.05 % of selected range and high output load stability
    Application
    PR electronics 3118 Bipolar isolated converter splitter
    The 3118 is an isolating converter and splitter which can be used for signal conversion of standard bipolar analog process signals into two individual unipolar analog signals.
    The unit offers 4-port isolation and provides surge suppression and protects control systems from transients and noise.
    The 3118 also eliminates ground loops and can be used for measuring floating signals.
    Mounting of the 3118 can be in Safe area or in Zone 2 and Cl. 1 Div 2 area and is approved for marine applications.
    The analog output can be easily configured and programmed to be bipolar in the ranges ±10 mA and ±20 mA (*special setup).
    Technical characteristics
    PR electronics 3118 Bipolar isolated converter splitter
    Flexible 24 VDC (±30%) supply via power rail or connectors.
    Excellent conversion accuracy, better than 0.05% of selected range.
    A green front LED indicates operation status for the device.
    All terminals are protected against overvoltage and polarity error.
    Meeting the NAMUR NE21 recommendations, the 3118 ensures top measurement performance in harsh EMC environments.
    High galvanic isolation of 2.5 kVAC.
    Fast input to output response time < 7 ms / > 100 Hz – 10 Hz bandwidth damping possible via DIP-switch.
    Excellent signalise ratio > 60 dB.
    Mounting / installation / programming
    PR electronics 3118 Bipolar isolated converter splitter
    Easy configuration of factory calibrated measurement ranges via DIP-switches.
    A very low power consumption allows DIN rail mounting without the need for any air gap.
    Wide temperature operation range: -25...+70°C.
    Environmental Conditions
    PR electronics 3118 Bipolar isolated converter splitter
    Operating temperature -25°C to +70°C
    Storage temperature -40°C to +85°C
    Calibration temperature 20...28°C
    Relative humidity < 95% RH (non-cond.)
    Protection degree IP20
    Installation in Pollution degree 2 & measurement / overvoltage cat. II
    Mechanical specifications
    PR electronics 3118 Bipolar isolated converter splitter
    Dimensions (HxWxD) 113 x 6.1 x 115 mm
    Weight approx. 70 g
    DIN rail type DIN EN 60715/35 mm
    Wire size 0.13 x 2.5 mm2 / AWG 26...12 stranded wire
    Screw terminal torque 0.5 Nm
    Common specifications
    PR electronics 3118 Bipolar isolated converter splitter 3118
    Supply
    Supply voltage 16.8...31.2 VDC
    Max. required power 0.8 W
    Internal power dissipation 0.4 W (typ.) / 0.65 W (max.)
    Isolation voltage
    Isolation voltage, test / working 2.5 kVAC / 300 VAC (reinforced)
    Zone 2 / Div. 2 250 VAC
    Response time
    Response time (0...90%, 100...10%) < 7 ms or < 44 ms
    MTBF, acc. to IEC 61709 (SN29500) > 187 years
    Signal / noise ratio > 60 dB
    Programming DIP-switches
    Cut-off frequency (3 dB) > 100 Hz or 10 Hz (selectable via DIP-switch)
    Accuracy < ±0.05% of span
    Temperature coefficient < ±0.01% of span / °C
    EMC immunity influence < ±0.5% of span
    Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
    Input specifications
    PR electronics 3118 Bipolar isolated converter splitter 3118
    Current input
    Measurement range -23...+23 mA
    Programmable measurement ranges ± 10 and ± 20 mA
    Input voltage drop < 1 VDC @ 23 mA
    Voltage input
    Programmable ranges ±5 and ±10 V
    Functional range -11.5...+11.5 V
    Input resistance ≥ 1 MΩ
    Selected Model
    PR electronics 3118 Bipolar isolated converter splitter 3118
    PR electronics 3103 Isolated repeater
    PR electronics 3108 Isolated repeater
    PR electronics 3109 Isolated converter / splitter
    PR electronics 3113 HART 7 temperature converter isolated
    PR electronics 3114 Isolated universal converter
    PR electronics 3117 Bipolar isolated converter
    PR electronics 3118 Bipolar isolated converter splitter
    PR electronics 3331 Temperature converter loop-powered isolated
    PR electronics 3333 Pt100 converter loop-powered
    PR electronics 3337 HART 7 temperature converter loop-powered
    PR electronics 4104 Universal uni-/bipolar signal transmitter
    PR electronics 4116 Universal transmitter
    PR electronics 4501 Display / programming front
    PR electronics 4511 Communication enabler
    PR electronics 3104 Isolated converter
    PR electronics 5714 Programmable LED indicator
    PR electronics 9116B Universal converter
    PR electronics 9410 Power control unit
    PR electronics 7501 Field mounted HART temperature transmitter
    PR electronics 5131A 2-wire programmable transmitter temperature transmitter
    PR electronics 5331A 2-wire programmable transmitter temperature transmitter
    PR electronics 5331D 2-wire programmable transmitter temperature transmitter
    PR electronics 5335D 2-wire programmable transmitter temperature transmitter
    PR electronics 5333A 2-wire programmable transmitter temperature transmitter
    PR electronics 5333D 2-wire programmable transmitter temperature transmitter
    PR electronics 5335A 2-wire programmable transmitter temperature transmitter
    PR electronics 5334A 2-wire programmable transmitter temperature transmitter
    PR electronics 5334B 2-wire programmable transmitter temperature transmitter
    PR electronics 5335A 2-wire transmitter with HART protocol temperature transmitter
    PR electronics 5337A 2-wire transmitter with HART protocol temperature transmitter
    PR electronics 5337D 2-wire transmitter with HART protocol temperature transmitter
    PR electronics 5350A PROFIBUS PA/FOUNDATION Fieldbus transmitter
    PR electronics 5350B PROFIBUS PA/FOUNDATION Fieldbus transmitter
    PR electronics 6331A 2-wire programmable transmitter temperature transmitter
    PR electronics 6331B 2-wire programmable transmitter temperature transmitter
    PR electronics 6333A 2-wire programmable transmitter temperature transmitter
    PR electronics 6333B 2-wire programmable transmitter temperature transmitter
    PR electronics 6334A 2-wire programmable transmitter temperature transmitter
    PR electronics 6334B 2-wire programmable transmitter temperature transmitter
    PR electronics 6335A 2-wire HART transmitter temperature transmitter
    PR electronics 6335D 2-wire HART transmitter temperature transmitter
    PR electronics 6337A 2-wire HART transmitter temperature transmitter
    PR electronics 6337D 2-wire HART transmitter temperature transmitter
    PR electronics 6350A PROFIBUS PA / FOUNDATION Fieldbus transmitter
    PR electronics 6350B PROFIBUS PA / FOUNDATION Fieldbus transmitter
    PR electronics 5131AB 2-wire programmable transmitter temperature transmitter
    PR electronics 5331A3B 2-wire programmable transmitter temperature transmitter
    PR electronics 5334A3B 2-wire programmable transmitter temperature transmitter
    PR electronics 5334B3B 2-wire programmable transmitter temperature transmitter
    PR electronics 5331D3B 2-wire programmable transmitter temperature transmitter
    PR electronics 6335D2A 2-wire HART transmitter temperature transmitter
    PR electronics 6331B2A 2-wire programmable transmitter temperature transmitter
    PR electronics 6335D2B 2-wire HART transmitter temperature transmitter
    PR electronics 6331B2B 2-wire programmable transmitter temperature transmitter
    PR electronics 6337D2A 2-wire HART transmitter temperature transmitter
    PR electronics 6334A2B 2-wire programmable transmitter temperature transmitter
    PR electronics 6350B2B PROFIBUS PA / FOUNDATION Fieldbus transmitter
    PR electronics 6334A2A 2-wire programmable transmitter temperature transmitter
    PR electronics 6337D2B 2-wire HART transmitter temperature transmitter
    PR electronics 6334B2A 2-wire programmable transmitter temperature transmitter
    PR electronics 6333B1B 2-wire programmable transmitter temperature transmitter
    PR electronics 6334B2B 2-wire programmable transmitter temperature transmitter
    PR electronics 6333B1A 2-wire programmable transmitter temperature transmitter
    PR electronics 6350A2A PROFIBUS PA / FOUNDATION Fieldbus transmitter
    PR electronics 6337A2B 2-wire HART transmitter temperature transmitter
    PR electronics 6337A2A 2-wire HART transmitter temperature transmitter
    PR electronics 5114AA 2-wire programmable transmitter temperature transmitter
    PR electronics 6331A2B 2-wire programmable transmitter temperature transmitter
    PR electronics 9106B HART transparent repeater
    PR electronics 9107B HART transparent driver
    PR electronics 9113B Temperature / mA converter
    PR electronics 9116B Universal converter
    PR electronics 9202B Pulse isolator
    PR electronics 9203B Solenoid / alarm driver
    PR electronics 7908 System 9000 backplane
    PR electronics 7916 System 9000 backplane
    PR electronics 5104B Ex repeater / power supply
    PR electronics 5105B Ex-isolated driver
    PR electronics 5106B HART transparent repeater
    PR electronics 5107B HART transparent driver
    PR electronics 5114B Programmable transmitter
    PR electronics 5115B Ex signal calculator
    PR electronics 5116B Programmable transmitter
    PR electronics 5203B Ex solenoid / alarm driver
    PR electronics 5202B Pulse isolator
    PR electronics 5131B 2-wire programmable transmitter
    PR electronics 5420B Ex power supply
    PR electronics 5223B Programmable f/I-f/f converter

    Contact Details
    HONGKONG XIEYUAN TECH CO., LIMITED

    Send your inquiry directly to us (0 / 3000)

    Other Products